One of the main functions of refrigeration systems is to decrease temperature of air flow. One thing that always occurs naturally along with decrease in temperature is the moisture reduction. In the air conditioning, for comfort or industrial, decrease of moisture is usually considered as desirable goal. In this case is emphasized on cooling and reduction of air humidity at temperatures range 5 to 35 oC.

Most of cooling coil is usually consists of pipe with fins attached to the outside, it is intended to expand surface area in contact with air. Generally, its convection coefficient is lower than water. Water flows inside pipe and air flows outside finned pipes.

Some terms and notions of cooling coil construction that as often used as follow:
-          Face area of the cooling coil: the cross-sectional area of air flow at the entrance of cooling coil.
-          Face velocity of the water: the volume of air flow rate is divided by surface area coil.
-          Surface area of the coil): the heat transfer surface area in contact with air.
-          Number of rows of tubes: i.e. number of rows (tubes, pipes) that are in the direction of air flow.
READ MORE - Cooling Coil

LMTD Heat Exchanger (Logarithmic Mean Temperature Difference)


The main factor to calculate and design heat exchanger is heat transfer problem. If amount of heat which is released is equal to Q with regulations of time, then cold fluid will receive heat as Q with equation:

Q = U . A . ΔTm

Where:
Q = released / received heat
U = overall heat transfer coefficient
A = area of ​​heat transfer
ΔTm  = Difference in average temperature
 
Before determining surface area of ​​heat (A), then the value of LMTD Heat Exchanger (Logarithmic Mean Temperature Difference) should be first determined. This is based on the difference in inlet temperature of fluid and outlet temperature of heat.

For different parallel flow direction of fluid, in which:

ΔTmax = ( T1 – t1 ) : ΔTmin = ( T2 – t2 )

For opposite luid flow, then:

ΔTmax = ( T1 – t2 ) : ΔTmin = ( T2 – t1 )

Where:
LMTD = Logarithmic Mean Temperature Difference
T1 = temperature of fluid into shell
T2 = temperature of fluid out of shell
t1 = temperature of fluid into tube
t2 = temperature fluid out of tube

In design heat exchanger, actual difference in average temperature should be calculated by using correction factor (Ft). Amount of actual difference in average temperature (ΔTm) is:

ΔTm = Ft × LMTD

READ MORE - LMTD Heat Exchanger (Logarithmic Mean Temperature Difference)

Fouling Factor in Heat Exchanger


Fouling Factor in Heat Exchanger greatly influence heat transfer process. This fouling can occur because sediment from flowing fluid. Fouling factor can be also caused by corrosion on components of heat exchanger due to the influence of the fluid type that flows through it.

During the heat exchanger is operated, fouling factor will inevitably occur. The occurrence of this fouling can disturb or affect temperature of fluid flow and can also reduce or affect the overall heat transfer coefficient of fluid.

Several fouling factors in heat exchanger as follow:
-          fluid temperature
-          wall tube temperature
-          velocity of fluid flow

Fouling factor in heat exchanger can be calculated by following equation:

where:
Uc = overall coefficient net of heat transfer
hio = coefficient of heat transfer on outside surface of tube
ho = coefficient of heat transfer fluid on outside tube
Ud = overall coefficient (design) of heat transfer 
READ MORE - Fouling Factor in Heat Exchanger

Shell and Tube Heat Exchanger Components


Shell and tube heat exchanger type is the heat exchanger type that is most widely used in oil and gas industries. This device consists of a shell in which there are some tube bundles which has relatively small diameter. One type of fluid flows inside tubes while the other fluid flow on outside tubes but still in the shell. In addition, this type has a lot of parts or components. Shell and tube heat exchanger components are shown in Figure 1.
Figure 1: Shell and Tube Heat Exchanger Components

Description:
  1. Channel fixed tip
  2. Hat fixed tip
  3. Channel fixed tip
  4. Channel cover
  5. Stationary head nozzles
  6. Stationary tubes sheet
  7. Tubes
  8. Shell
  9. Shell Cover
  10. Stationary shell flange head end
  11. Shell flange - Rear Head End
  12. Shell Nozzle
  13. Shell cover flange
  14. Expansion Joint
  15. Floating Head Cover
  16. Floating Head Cover
  17. Floating Head Flange
  18. Head Floating Backing Device
  19. Split Ring Shear
  20. Slip - on backing flange
  21. Floating Head Cover
  22. Floating Tube Sheet Skirt
  23. Packing box flange
  24. Packing
  25. Packing follower ring
  26. Lantern Ring
  27. Tie Rod and Spacer
  28. Transverse baffles or Support Plate
  29. Impingement baffles
  30. Longitudinal baffles
  31. Pass partition
  32. Vent Connection
  33. Connection

READ MORE - Shell and Tube Heat Exchanger Components

Types of Heat Exchangers


Many types of heat exchangers can be found in industrial world and power plant. Heat exchanger has a lot of types; each type consists of tools that have been standardized to name tools and parts of heat exchanger by the association of heat exchanger maker which is known as Tubular Exchanger Manufactures Association (TEMA). Standardization aims to protect the user from harm or damage to equipment, because heat exchanger is operating at high temperature and pressure.

In a standard mechanical TEMA, there are two classes of heat exchanger, namely:
  1. Class R, which is for equipment that works with serious conditions, such as oil and heavy chemical industry.
  2. Class C, which is made ​​for general purpose, based on economically and small size, used for general industrial processes.

Types of Heat Exchanger contained in the petroleum industry can be divided into:
  1. Shell and Tube Heat Exchanger Type
  2. Double Pipe Heat Exchanger Type
  3. Coil Pipe Heat Exchanger Type
  4. Open Tube Section Type
READ MORE - Types of Heat Exchangers

Heat Exchanger Applications


There are many applications of heat exchanger in our daily life. The following below is some examples heat exchanger applications and its function:

  1. Chiller
Chiller is one of heat exchanger applications that is used to cool fluid until low temperature. Temperature of fluid that is resulted from cooling process in the chiller is lower than temperature of cooling fluid cooling which is performed by cooling water. For this chiller, used cooling medium normally is ammonia or Freon.

  1. Condenser
Condenser is one of heat exchanger applications that is used to cool steam or mixture of steam, so it turns into liquid phase. Cooling medium used is usually water or air.  Steam or steam mixture will release latent heat to the coolant, for example in steam boiler power plants that use condensing turbine. Used steam from turbine will be entered into condenser, and then condensed into condensate.

  1. Cooler
Cooler is one of heat exchanger applications that is used to cool liquids or gases by using water as cooling medium. Here no phase change, with today's technological developments then cooler use cooling medium as air with the aid of fan.

  1. Evaporator
Evaporator is one of heat exchanger applications that is used for evaporation of liquid into steam. Evaporation process convert liquid phase into steam phase. Evaporator utilizes latent heat to convert liquid phase into steam phase.

  1. Re-boiler
Re-boiler is one of heat exchanger applications that serve to re-boil and partially vaporize the liquid being processed. The heating medium is often used steam or hot substance that is being processed itself. One of example application of re-boiler is oil refinery system that use oil (665 F) as a medium evaporator, the oil will come out of boiler and flows inside tube.

  1. Heat Exchanger
Heat exchanger is one of heat exchanger application which is intended to utilize heat of fluid flow to another.  Heat exchanger has two functions as follow:
-          Heating the fluid
-          Cool the hot fluid
Temperatures in and out of both fluid types are set according to its needs.

READ MORE - Heat Exchanger Applications

Design Shell and Tube Heat Exchanger


Many alternative designs can be used in the design of shell and tube heat exchangers but need for optimizing design to reduce costs. There needs to be trial and error techniques to get most optimal design. Some parameters and constraints used in the design shell and tube heat exchanger are:
  1. Inlet temperature and outlet temperature.
  2. Fluid mass flow rate.
  3. Operating pressure.
  4. Pressure loss / drop that is allowed on both sides of heat exchanger.
  5. The properties of fluid.
  6. Fouling resistance for each flow.

In designing we also have to consider a decrease in pressure inside tube and inside hell. In addition, there are also some parameters of limitation, namely:
  1. The maximum velocity inside tube. When velocity of fluid flow inside tube is too high erosion will occur.
  2. The minimum velocity inside tube. The rate of fouling can increase if fluid velocity inside tube is too small.
  3. Tendency of vibrations on tubes. Many failures in heat exchanger is caused by the occurrence of flow-induced vibration on tubes. This event occurs because there is critical velocity in tubes that can cause vibrations on the tube.

READ MORE - Design Shell and Tube Heat Exchanger

Parts Shell and Tube Heat Exchanger


Parts of shell and tube heat exchanger as following below:

  1. Shell
Shell is usually made of steel and alloys. Dimension and wall thickness of shell is set by TEMA standard in inch and millimeter unit ranging from 6 inches (152 mm) to 100 inches (2540 mm) for shell diameter and 1/8 inch (3.2 mm) up to ½ inch (12.7 mm) for thickness. While material that is used for shell specification is recommended refer to ASTM standard. For the shell cover, minimum thickness is equal to thickness of shell.

Figure 1 shows mechanical arrangement of shell and tube heat exchanger. Figure 1(a) shows arrangement of one shell and tube single-pass, while Figure 1(b) to Figure 1(d) shows arrangement of one shell and two tube-passes. Figure 1(b) is arrangement for U-tube type. Figure 1(c) for fixed tubesheet and Figure 1(d) for floating tubesheet.
Figure 1: Mechanical Arrangement of Tube and Shell Heat Exchanger

  1. Tube
Characteristics of tube in heat exchanger have major effect on heat transfer between working fluid. These characteristics include dimensions, materials, and arrangements. The dimension of tube is available in inch unit. In TEMA standards, outside diameter of tube is limited ranging from ¼ inch (6.4 mm) up to 2 inch (50.8 mm). Wall thickness of tube is related to thermal resistance on the side of tube wall, thicker wall thickness means that tube has higher thermal resistance and has lower quality to heat transfer. Tube materials are available for manufacture of tube is usually in the form of carbon steel and its alloys, nickel and its alloys, and aluminum and its alloys.

  1. Baffle
Baffle serves as partition to direct fluid flow inside shell and increase flow rate or make the flow becomes turbulent. The presence of turbulence will increase heat transfer coefficient so it will increase the rate of heat transfer. Nevertheless, installation of baffle also increases pressure drop of fluid flow. Baffle is mounted on the tie rod.

In TEMA standards, distance between one baffle to other baffle is set and it is called as baffle spacing. The distance between one baffle to one another is made same, if not possible then be taken to nearest distance is adjacent section with the edge of  shell, while other distance is made same distance between one baffle to other baffle.

The closest distance between baffle is limited 1/5 diameter of the shell. This aims to avoid too high pressure drop, while the furthest distance is usually not greater than diameter of shell, it aims to avoid occurrence of vibration on the pipe. In case of vibration, then tube that is mounted on tubesheet will also vibrate and potentially to create leak.

  1. Tie Rod
Tie rod is a rod with certain diameter that serves as baffle support. Tie rod attached to the tubesheet with screw mechanism, while at the other end is equipped with couple bolt and screw to hold baffles keep arriving at his position. TEMA standards set dimension diameter tie rod as a function of inside diameter of shell, the larger inside diameter of shell, diameter of tie rod will aso greater and number of baffles will increase because of the greater size and weight of baffle.

  1. Tubesheet
Tubesheet function is as place of tube installation. The arrangement of installed tubes can be shaped triangular, rotated triangular, square, and rotated square. Tubes are usually installed not symmetrical. Asymmetry is found in section adjacent to nozzle, a place where fluid flow into shell. At this place, there is not tube to aims to minimize contraction that occurs in tubes as an effect of fluid flow enters shell.

  1. Tube Pitch
In TEMA standards is arranged that the shortest distance is 1 - 1/4 times from center point of tube. The shortest distance between two holes is usually called as clearance. The advantages of square pitch form are the ease of maintenance mechanic because there is a regular clearance position to form horizontal and vertical line and also has low pressure drop because there is not blocking fluid flow.

If higher rate of heat transfer is desired, tube pitch type can choose triangular pitch type. In this type, fluid can not flow smoothly because it was blocked by tubes in front of it, causing turbulence and pressure drop becomes large. Mechanical maintenance (cleaning crust on outside tube) of triangular pitch type is more difficult because scrubber brush can not pass clearance easily. The existence of triangular tubes arrangement blocks the scrubber brush.

READ MORE - Parts Shell and Tube Heat Exchanger

Advantages of Shell and Tube Heat Exchanger


Although today is very much type of heat exchanger that was developed in industries, but the shell and tube heat exchanger type is more widely used than other types. This is due to several advantages of shell and tube heat exchanger type as follow:

-          Configuration shell and tube heat exchanger type provide large surface area with small shape or volume.
-          This heat exchanger type has good mechanical lay-out and good shape for pressurized operation.
-          Shell and tube heat exchanger type use well-established fabrication techniques.
-          This heat exchanger type can be made ​​with different materials in which selected materials can be used in accordance with operating temperature and operating pressure.
-          Easy to clean shell and tube heat exchanger type.
-          This heat exchanger type has well-established planning procedures.
-          Its construction is simple and can uses relatively small room.
-          The procedure of shell and tube heat exchanger type is not difficult, very easy to be known and understood by operator that has low educational background.
-          The construction of this heat exchanger type can be split to each other; it is not a unity, so the transportation is relatively easy.

READ MORE - Advantages of Shell and Tube Heat Exchanger

Shell and Tube Heat Exchanger

Shell and tube heat exchanger is the heat exchanger type that is most widely used in industrial process. This is because the type of shell and tube can be used for processes with large range of variations in pressure and temperature. In addition, another advantage of shell and tube heat exchanger type is can be constructed with wide range of material variations. Shell and tube heat exchanger can be divided into three main types. The composition of shell and tube heat exchanger type is conventionally classified according to nomenclature of Tubular Exchanger Manufacturers Association (TEMA).

The three classifications of tube and shell heat exchanger as following below:
  1. Fixed Tubesheet Type of Shell and Tube Heat Exchanger
This type is very modest when compared with the two next types. The characteristic of fixed tubesheet type is the presence of fixed or stationary tubesheet. In terms of maintenance, mechanical or chemical method can be applied to the inner side of pipe. Mechanical method is done by using cleaning brush, while chemical method uses chemical liquid that is sprayed into pipe. The difficulty will occur is if there is crust, scale, or deposit attached on on the outside of pipe, so the cleaning method cannot be performed because construction of fixed tubesheet will not allow technician clean the crust from the outside.

The disadvantage of fixed tubesheet type is it cannot resist high thermal expansion that will cause leak on the side of tubesheet. Therefore, this heat exchanger type is not recommended for use at too high temperature. The addition of expansion space is needed to overcome thermal expansion problem.

  1. U - Tube Type of Shell and Tube Heat Exchanger
U - Tube has form that is not too complex like fixed tubesheet type so that the cost of manufacture is not too expensive. This heat exchanger type has U-shaped pipe. The advantage of this type is the ease of maintenance at the outside of pipe by remove tube bundle. After tube bundle are removed from shell, the mechanical cleaning on the outside of pipe or on the side of shell can be easily done.

In contrast to U-shaped pipe, the cleaning by mechanical method is quite difficult for the inside of pipe due to due to the U-bend causes scrubber brush can not reach this part. Furthermore the cleaning method is more recommended to use chemical liquid. Another advantage of this type is thermal expansion will occur on the side of pipe bend so it can resist thermal expansion well.

  1. Floating Head Type of Shell and Tube Heat Exchanger
This heat exchanger type has most complex arrangement when compared with the previous two types. This is because of floating head cover that causes the cost of manufacture is more expensive. Floating head type is very appropriate when working at high pressure and temperature condition. The existence of thermal expansion will be received by floating head cover. Tube bundle of heat exchanger consists of straight pipe arrangement which is strongly installed on the edges.

Tubesheet diameter on the inlet side of fluid has larger diameter than the diameter of  shell, whereas on the other side, the tubesheet diameter has smaller dimension than the diameter of shell. The purpose of election of this configuration is to make easy for move  in translational if thermal expansion occur on the side of floating head cover. The maintenance at the isnside and outside of pipe can be done easily. Maintenance for outside pipe can be done by removing tube bundle while for  inside pipe can be carried out by using scrubber brush or  chemical liquid.

READ MORE - Shell and Tube Heat Exchanger

Component of Economizer

Economizer has a role as a heat exchanger to increase temperature of feedwater before to be supplied into steam drum. Economizer consists of similar component with other heat exchanger but on the certain parts has different task and function. The following below are the component of economizer

-          Shell, is one of parts in economizer which be like a house for tubes and header. Between tubes and header, there are fluids that can receive and release heat in accordance with occurred mechanism.

-          Tubes, is the most important component of economizer in the process of heat transfer. Fluids flow both inside and outside tube. The flowing fluid has different capacity, temperature, density and pressure. Position of tube must be maintained to prevent vibration, so on certain design, tubes is supported with baffle. Tube should also be able to transfer heat between the fluids inside tube and outside tubes.

Determination material of tube should follow these requirements; tube should have capability to transfer high heat, has resistance to heat, corrosion, and erosion and has well other properties. Capability to receive and release heat is also affected by amount of surface area.

-          Baffle, is one of component in economizer that has some roles such as to support tube and maintain its position, baffle also has function to prevent vibration on the tube and control and direct the flow of fluid outside tubes.

Baffle can be classified based on construction as follow: segment baffle, rod baffle, horizontal baffle and impingement baffle. These types of baffle are usually used independently but in the special needs, one type and other type can be combined.

-          Header, is the component of economizer as a water collector and distribute water to each tubes evenly. Header has two types; upper header and lower header. Tubes are connected into header, so header has size and mount of hole in accordance with tubes condition.

-          Tie rods and spacer, are one of part economizer to maintain position one baffle and other baffle so vibration can be prevented.
READ MORE - Component of Economizer

Mechanism of Economizer

Economizer is one of steam boiler’s equipment which is used to heat feedwater before it is supplied into steam drum. Economizer is the heat exchanger equipment to increase boiler efficiency by absorbing heat recovery of flue gases. The lower temperature of flue gas out from stack, the heat loss will be less and the fuel which is needed to convert water into steam will be also less in certain circumstances. So it can be said that economizer can save the fuel efficiently.  Economizer will make temperature of feedwater higher, so steam boiler can produce steam easily.

The heating process of water in the economizer is like an heat exchanger, water is distributed inside tubes and flue gas outside tubes. The hot flue gas outside tubes flow and making contact with outside surface tube, so the heat transfer occur between hot flue gas and surface metal tubes by convection. Water inside tubes receives heat transfer from metal tubes, so temperature of water is higher than before enter economizer. Contact of flue gas flow to feedwater flow is regular and perpendicular. It is controlled and regulated by setting the flue gas flow.

Furthermore, feedwater that has been heated in economizer is sent to steam drum through connecting pipes. In the steam drum, feedwater will be boiler water and be heated again in water wall tubes to be saturated steam and superheater will make it as superheated steam.

The advantages of using economizer as initial heater are as follow:
-         The metal wall of steam drum will not easy to be contracted, shrivel and broken because the incoming water is not cold condition so the cost maintenance will be smaller.
-         Increase steam boiler efficiency and decrease heat loss.
-         Save the fuel needed to perform combustion process
-         The size of furnace can be smaller because the requirement heat surface is less than without using economizer.