Requirement design of economizer
is made to ensure that steam boiler can be performed efficiently. The requirement
design of economizer should describe the provisions for preventing thermal
fatigue damage to the economizer inlet manifolds, headers and tubing due to feed
temperature cycling during hot banked conditions and start up. The economizer
and its circulating system should be designed so as to avoid any serious water
hammer caused due to steaming in the economizer tubes.
The economizer tubes can be
seamless material. The economizer should be of a continuous loop drainable type
and arranged for the upward flow of water and downward flow of flue gas. Staggered
spacing and extended fins or studs will not be accepted. The minimum tube
spacing should be not less than the spacing of the horizontal tubes which are
located above economizer.
The economizer heating surface should
be of effective heat transfer design, consistent with the minimum cross sectional
free flow area in the tube bundle. The entire tube arrangement should be
drainable.
Thermocouples with protection
wells should be provided in the requirement design of economizer. Where
required for access and inspection, doors should be provided with tight gasket
joints.
All headers should be external to
the gas stream except economizer inlet and junction headers which are located
at low gas temperature area, and should be provided with welded inspection hole
covers as required for inspection. The header in the gas stream should be
shielded to avoid header damage caused by the flue gas. Inlet and outlet
headers and/or lead pipes should have thermo wells with thermocouples and connections
for pressure gauge and test gauge furnished in the requirement design of economizer.
Feedwater connection at the
terminal point should be welded type and material to match Power piping. Double
drain valves should be provided in the requirement design of economizer. In the
case of extended surface type finned tube, a special consideration should be
made in order to avoid undue fouling or plugging with ash.
The economizer tubes should be
arranged to permit the installation and easy replacement of soot blowers and to
permit future installation of additional soot blowers. The economizer support should
be designed to permit free expansion of all pressure parts and to prevent
excessive expansion stresses on the boiler.
The tube spacing of the
economizer should be designed to minimize bridging and to avoid tube erosion. Sufficient
numbers of baffle plates should be installed at convection zone, including
economizer. Manholes installed on the baffle plates of economizer should be of
the sliding door type. The casing should be gas tight, and sufficient access
door for entrance should be provided at each section of the requirement design
of economizer.